Mã sản phẩm:
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
CTP‑I2 | Guard locking actuated by power-ON applied and spring released (open-circuit current principle). |
Plug connector (view of connection side) |
Pin |
Designation |
Function |
Conductor coloring of connection cable |
---|---|---|---|---|
1 |
IMP |
Guard locking solenoid control input, 24 V DC |
WH |
|
2 |
UB |
Operating voltage of AP electronics, 24 V DC |
BN |
|
3 |
FO1A |
Safety output, channel 1 |
GN |
|
4 |
FO1B |
Safety output, channel 2 |
YE |
|
5 |
OI |
Diagnostics output |
GY |
|
6 |
OD |
Door monitoring output |
PK |
|
7 |
OL |
Guard locking monitoring output |
BU |
|
8 |
0 V |
Operating voltage of AP electronics, 0 V/control input of guard locking solenoid, 0 V |
RD |