  • Features

    • Safety switch with guard locking and integrated evaluation electronics
    • Short circuit monitoring
    • 2 safety outputs (semiconductor outputs)
    • Up to category 4/PL e according to EN ISO 13849-1
    • With plug connector M23
    • Unicode
    • Door monitoring output
    • Approach direction A, B and C (default setting on delivery)

    Approach direction

    Horizontal

    Can be adjusted in 90° steps

    Unicode evaluation

    Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.

    Guard locking type

    CTP‑L2 Guard locking actuated by power-ON applied and spring released (open-circuit current principle).

    Connector assignment

    Plug connector (view of connection side)

    Pin

    Designation

    Function

    Conductor coloring of connection cable

    1

    IMP

    Operating voltage of guard locking solenoid, 24 V DC

    VT

    2

    -

    n.c.

    RD

    3

    -

    n.c.

    GY

    4

    FO1A

    Safety output, channel 1 

    RD/BU

    5

    FO1B

    Safety output, channel 2 

    GN

    6

    UB

    Operating voltage of AP electronics, 24 V DC

    BU

    7

    RST

    Reset input

    GY/PK

    8

    OD

    Door monitoring output

    GN/WH

    9

    OI

    Diagnostics output

    YE/WH

    10

    OL

    Guard locking monitoring output

    GY/WH

    11

    -

    n.c.

    BK

    12

    FE

    Function earth (must be connected to meet the EMC requirements)

    GN/YE

    13

    -

    n.c.

    PK

    14

    -

    n.c.

    BN/GY

    15

    -

    n.c.

    BN/YE

    16

    -

    n.c.

    BN/GN

    17

    -

    n.c.

    WH

    18

    IMM

    Operating voltage of guard locking solenoid 0 V

    YE

    19

    0 V UB